| Home | About Us | What We Offer | Contact Us | Enquiry |
|
Welding Penetration Inspection System Metallurgical Image Analysis System Coating Thickness Gauge Pocket-Surfix: 3 D Coordinate Measuring Machine (3D CMM)
Showcase |
Coating Thickness Gauges
|
| We offer Coating Thickness Gauges that is compact and light weight. Provided with digital LED screen, the gauge is widely used for measurement of varnish, electroplated coating and paint on iron and steel. It ensures easy operation and provide accurate readings.
We offer coating thickness gauges as per the requirement and specification of clients. SURFIX F/N/FN The portable coating thickness gauge with mobile phone-type menu.
Specification:
Measuring range: 0- 1500µm/0-60 mils (measuring unit operator selectable). Tolerance:± (1µm + 3% ofreading) / ±(0.004 mils+ 3% of reading) Resolution : 0.1µm / 0.004 mils 0r 2% of reading Display : back-light, 4-digit, Alphanumeric, digit, height:10mm / 0.4" Minimum Measuring: 5mm x 5mm / 0.2"/.02" Minimum Curvature radius:convex 3mm / 0/12" X 0.12 concave : 50 mm/2" Minimum substrate thickness: type F: 0.5mm/20mils, type N-50µm/2mil Calibration: factory calibration, zero calibration, foil calibration Statistics: number of readings, mean value, standard deviation, maximum and minimum reading of max.10000values. Data memory: Max.80 readings, available singly, statistical value Limits: adjustable with acoustic alarm system Interface: Infra-red Power supply: 2 x mignon alkaline batteries (AA)1.5v Probe: ø14mm x 83mm/0.56"dia X 3.3" Standards: DIN, ISO,ASTM,BS |
| Coating thickness gauge Pocket-Surfix: · All non-ferrous coatings such as varnish, paint, enamel, chrome, copper, zinc, etc on steel and iron (magnetic induction method) and all electrically insulating coatings, such as varnish, paint, anodizing coatings on non-ferrous metals, also on stainless steel (eddy-current method) · Dual-purpose gage for measurement on steel and on non-ferrous metals · Automatic ferrous/non-ferrous substrate recognition. Always measures correctly · No calibration necessary unless required · Easy-to-operate menu structure in display. Instruction manual is supplied with gauge, but not necessary for operation. · Three-language option: German, English, French; other languages on request · Measured value memory, statistical memory · Data transfer to printer or PC via an infrared interface
Magnetic induction principle (F-Mode) for ferrous metals
(4.2 ” x 2 ” x 1 ”) Weight: 90 g (3.2 oz) incl. batteries
Minimum Radius for Convex Surfaces 1.5 mm (0.06 ”) Minimum Radius for Concave Surfaces 50 mm (2 ”) Minimum Headroom 125 mm (5 ”) Minimum 10 mm x 10mm Measuring Area (0.4 ” x 0.4 ”) Minimum Substrate Thickness – F 0.2 mm (8 mils) Minimum Substrate Thickness – N 50 μm (2 mils)
Pocket-Surfix for FN-Version: Gauge incl. probe, 2 calibration foils, ferrous and non-ferrous zero plate, 2 AAA batteries, carrying pouch, manual and manufacturer’s certificate. |
| Surfix® Pro S MAKE PHYNIX Germany Probe: The V-notched foot of the standard probes provides a stable footing even on small cylindrical parts. It can be removed to expose a “micro-probe” sensor perfect to measure on small measuring areas and in cavities. Features: • Innovative and user-friendly measuring techniques • Large data memory for 10000 readings • Input and managing of alphanumerical file names • Online statistics with all common parameters • Data transfer to printer/PC via infrared or serial interface • The Surfix® Pro S automatically identifies the substrate and activates the appropriate measuring procedure • The scan mode enables a continuous measurement • Free choice of different languages ensures easy operation • The uniform contact pressure of the sensor is minimized, preventing scratches & indentations to sensitive surfaces • Optional high temperature foot for measuring on surfaces up to 150 °C (302 °F)
Machine Includes: Gauge incl. probe, 2 calibration foils, ferrous and non-ferrous zero plate, 2 AA batteries, transfer program FixSoft, manual and manufacturer’s certificate; all in a rugged plastic carrying case. Carrying pouch optional.
Measuring principle: Magnetic induction principle (F-Mode) for ferrous metals Eddy-current principle (N-Mode) for non-ferrous metals FN-Mode for all metals Range: 0 – 1500 μm (0 – 60 mils) Accuracy: ± (1 μm/ 0.04 mils + 1 % of reading) Resolution: 0.1μm/ 0.004 mils or < 0.2 % of reading Display: Backlight, 4-digit alphanumeric, height 10 mm (0.4 ”) Min. Measuring Area: 5 mm x 5 mm (0.2 ” x 0.2 ”) Min. Curvature Radius: Convex: 01.5 mm (0.06 ”) Concave: 05.0 mm (0.20 ”) Min. Substrate Thickness: Ferrous: 00.2 mm/ 8 mils Non-Ferrous: 50.0 μm / 2 mils Calibration: Factory-, zero-, foil-, two-foil-, CTC-calibration Offset-function: add. or subtract. of a constant value Memory: 10000 readings in max. 250 selectable files, alphanumerical file names, stored readings and statistical values individually recallable Statistics Program: Single-/block-value: n, x _ , s, kvar, min, max, cp, cpk Data Output: Infrared and serial RS232 interface Power: 2 AA, 1.5 V Dimensions: 137 mm x 66 mm x 23 mm (5.4 ” x 2.6 ” x 0.9 ”) Weight: 225 g (8 oz) incl. FN 1.5 probe and batteries Protection Class: IP 52 (proof against dust and dripping water)Standards: DIN, ISO, ASTM, B Test-Stand (optional) • Designed for smooth, repeatable measurements for coating thickness applications • Spring-loaded lever for fast, precise travel • Compact size and light weight makes it the ideal test stand for all workplaces Optional accessories: Printer Print, FixSoftware ProSoft (optional)
|
|
Contact Us
|
Home | About Us | What We Offer | Media Gallery | Jobs & Opportunities | Site Map | Contact Us | Enquiry
© QS Metrology Private Limited. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited
|