Gauge |
Supports multiple probes Automatically identifies substrate type and activates appropriate measuring procedure Scan mode enables continuous measurement Automatic identification of probe type used Supports units µm and mils |
Memory |
Large data memory for 100,000 readings, 1,000 selectable files, Free choice of filename Saved readings and statistical values individually recallable |
Data Output | Data transfer via USB 2.0 und Bluetooth 4.0 |
Statistics | Single and block value, selectable block size Parameter: n, x¯ , s, Min, Max, Kvar, cp, cpk |
Calibration |
Factory, Zeroing (1-point calibration), Zero offset: addition/subtraction of a constant value to/from the reading |
Protection class | Protection class – IP 52 (proof against dust and dripping water) |
Display |
High resolution Color display Backlight, 4-digit alphanumeric |
Standards |
DIN, ISO, ASTM, BS |
Measuring Principle |
Magnetic induction principle (F-Mode) Eddy-current principle (N-Mode) |
Limit values | Freely selectable; optical and acoustic signal if limit value is exceeded |
Accuracy | Please refer supported probes |
Resolution | Please refer supported probes |
Range |
0 – 200 µm for Iron/Steel (FN & F models) 0 – 200 µm for Non-Ferrous metals (FN and N Models) |
Substrate | Ferrous and Non-Ferrous |
Tolerance | ± (0.7 µm + 1 % of reading) |
Resolution | 0.1 µm or < 0.2 % of reading |
Min. Area of measurement | 5 mm x 5 mm |
Minimum radius of curvature |
Convex 1.5 mm, Concave 5 mm |
Minimum thickness of substrate |
Iron/Steel: 0.2 mm Non-ferrous metals: 50 µm |
Surface Temperature | -15 °C to 60 °C |
Range |
0 – 1,500 µm for Iron/Steel (FN & F models) 0 – 1,500 µm for Non-Ferrous metals (FN and N Models) |
Substrate | Ferrous (FN/F)and Non-Ferrous (FN/N) |
Tolerance | ± (1 µm + 1 % of reading) |
Resolution | 0.1 µm or < 0.2 % of reading |
Min. Area of measurement | 5 mm x 5 mm |
Minimum radius of curvature |
Convex 1.5 mm, Concave 5 mm |
Minimum thickness of substrate |
Iron/Steel: 0.2 mm (FN and F Model) Non-ferrous metals: 50 µm (FN and N Model) |
Surface Temperature | -15 °C to 60 °C |
Minimum ID for measurement (for FN 1.5/90) | 12.5 mm |
Range |
0 – 3,500 μm – For Iron/Steel 0 – 3,000 μm – For Non-Ferrous substrates |
Accuracy | ± 3 μm or ± 3 % of reading (whichever is greater) |
Resolution |
1 μm for 0 to 1,000 μm 2 μm for 1,000 to 2,500 μm 5 μm for 2,500 to 3,500 μm |
Min radius for convex surface | 5 mm |
Min radius for concave surface | 50 mm |
Min measuring area | 10 mm X 10 mm |
Range | 0 – 10 mm – For Iron/Steel |
Accuracy | ± 10 μm or ± 3 % of reading (whichever is greater) |
Min radius for convex surface | 5 mm |
Min radius for concave surface | 50 mm |
Min measuring area | 10 m X 10 mm |
Reviews