QS Metrology | Portable XRF Analyser | Portable XRF Spectrometer | Optical Emission spectrometer | XRD | Surface roughness Tester | roughness measuring machine | Portable Roughness Tester | Contour measuring machine | Contour Tester | Coordinate measuring machine | 3 D Coordinate measuring machine | Weld penetration inspection | Weld penetration measurement System | Stereomicroscope | Coating thickness tester | Video Measuring machine | Metallurgical Image analysis | Metallurgical microscope

Surfix® Pro X

The new premium product Surfix® Pro X features a large high-contrast color display and is apted to make large sets of measurements during production or in the laboratory.

Surfix® Pro X
Surfix® Pro X

Surfix® Pro X

The new premium product Surfix® Pro X features a large high-contrast color display and is apted to make large sets of measurements during production or in the laboratory. Integrated USB and Bluetooth Interfaces make for an easy network Connection

  • Detachable probe model
  • Colour display
  • Large data memory of up to 100,000 readings
  • Up to 1,000 individual calibrations
  • Free choice of file names
  • Statistics
  • USB and Bluetooth interface
  • Multiple probe options
  • Continuous measurement (up to 3 readings per second)
  • DIN, ISO, ASTM, BS standards
  • IP 52 (protection against dust and dripping water)
  • Electroplating
  • Paint shops
  • Automotive industry
  • Chemical industry
  • Aerospace industry
  • Ship building industry
  • Tyre industry
  • Quality management and final inspections
  • Laboraties and research facilities 
Gauge Supports multiple probes
Automatically identifies substrate type and activates appropriate measuring procedure
Scan mode enables continuous measurement
Automatic identification of probe type used
Supports units µm and mils
Memory Large data memory for 100,000 readings, 1,000 selectable files, Free choice of filename
Saved readings and statistical values individually recallable
Data Output Data transfer via USB 2.0 und Bluetooth 4.0
Statistics Single and block value, selectable block size Parameter: n, x¯ , s, Min, Max, Kvar, cp, cpk
Calibration Factory, Zeroing (1-point calibration), Zeroing and foil calibration (2-point calibration), Two-foil calibration, Zero offset: addition/subtraction of a constant value to/from the reading
Protection class Protection class – IP 52 (proof against dust and dripping water)
Display High resolution Color display Backlight, 4-digit alphanumeric Switchable backlight, Selectable between µm/mils
Standards DIN, ISO, ASTM, BS
Measuring Principle Magnetic induction principle (F-Mode) Eddy-current principle (N-Mode)
Limit values Freely selectable; optical and acoustic signal if limit value is exceeded
Accuracy Please refer supported probes
Resolution Please refer supported probes
Warranty 1 Years

Supported Probes

Range 0 – 200 µm for Iron/Steel (FN & F models) 0 – 200 µm for Non-Ferrous metals (FN and N Models)
Substrate Ferrous and Non-Ferrous
Tolerance ± (0.7 µm + 1 % of reading)
Resolution 0.1 µm or < 0.2 % of reading
Min. Area of measurement 5 mm x 5 mm
Minimum radius of curvature Convex 1.5 mm, Concave 5 mm
Minimum thickness of substrate Iron/Steel: 0.2 mm Non-ferrous metals: 50 µm
Surface Temperature -15 °C to 60 °C
Range 0 – 1,500 µm for Iron/Steel (FN & F models) 0 – 1,500 µm for Non-Ferrous metals (FN and N Models)
Substrate Ferrous (FN/F) and Non-Ferrous (FN/N)
Tolerance ± (1 µm + 1 % of reading)
Resolution 0.1 µm or < 0.2 % of reading
Min. Area of measurement 5 mm x 5 mm
Minimum radius of curvature Convex 1.5 mm, Concave 5 mm
Minimum thickness of substrate Iron/Steel: 0.2 mm (FN and F Model) Non-ferrous metals: 50 µm (FN and N Model)
Surface Temperature -15 °C to 60 °C
Minimum ID for measurement (for FN 1.5/90) 12.5 mm
Range0 – 1,500 µm for Iron/Steel
0 – 1,500 µm for Non-Ferrous metals
SubstrateFerrous and Non-Ferrous
Tolerance± (1 µm + 1 % of reading)
Resolution0.1 µm or < 0.2 % of reading
Min. Area of measurement5 mm x 5 mm
Minimum radius of curvature

Convex 1.5 mm, 

Concave 5 mm

Minimum thickness of substrateIron/Steel: 0.2 mm (FN and F Model)
Non-ferrous metals: 50 µm (FN and N Model)
Surface Temperature -15 °C to 60 °C
Minimum ID for measurement 12.5 mm
Range

0 – 3,500 μm – For Iron/Steel

0 – 3,000 μm – For Non-Ferrous substrates

Accuracy

± 3 μm or ± 3 % of reading

(whichever is greater)

Resolution

1 μm for 0 to 1,000 μm

2 μm for 1,000 to 2,500 μm

5 μm for 2,500 to 3,500 μm

Min radius for convex surface5 mm
Min radius for concave surface50 mm
Min measuring area10 mm X 10 mm
Range 0 – 10 mm – For Iron/Steel
Accuracy ± 10 μm or ± 3 % of reading (whichever is greater)
Min radius for convex surface 5 mm
Min radius for concave surface 50 mm
Min measuring area 10 mm X 10 mm
  • Electroplating
  • Paint shops
  • Automotive industry
  • Chemical industry
  • Aerospace industry
  • Ship building industry
  • Tyre industry
  • Quality management and final inspections

Laboraties and research facilities 

  • Detachable probe model
  • Colour display
  • Large data memory of up to 100,000 readings
  • Up to 1,000 individual calibrations
  • Free choice of file names
  • Statistics
  • USB and Bluetooth interface
  • Multiple probe options
  • Continuous measurement (up to 3 readings per second)
  • DIN, ISO, ASTM, BS standards
  • IP 52 (protection against dust and dripping water)

Gauge

Supports multiple probes

 

Automatically identifies substrate type and activates appropriate measuring procedure

 

Scan mode enables continuous measurement

 

Automatic identification of probe type used

 

Supports units µm and mils

Memory

Large data memory for 100,000 readings, 1,000 selectable files, Free choice of filename

 

Saved readings and statistical values individually recallable

Data Output

Data transfer via USB 2.0 und Bluetooth 4.0

Statistics

Single and block value, selectable block size 
Parameter: n, x¯ , s, Min, Max, Kvar, cp, cpk

Calibration

Factory, Zeroing (1-point calibration),
Zeroing and foil calibration (2-point calibration),
Two-foil calibration,
Zero offset: addition/subtraction of a constant value to/from the reading

Protection class

Protection class - IP 52 (proof against dust and dripping water)

Display

High resolution Color display

Backlight, 4-digit alphanumeric
Switchable backlight, Selectable between µm/mils

Standards

DIN, ISO, ASTM, BS

Measuring Principle

Magnetic induction principle (F-Mode)

Eddy-current principle (N-Mode)

Limit values

Freely selectable; optical and acoustic signal if limit value is exceeded

Accuracy

Please refer supported probes

Resolution

Please refer supported probes

Warranty

2 Years

Supported Probes

Range 0 – 200 µm for Iron/Steel (FN & F models) 0 – 200 µm for Non-Ferrous metals (FN and N Models)
Substrate Ferrous and Non-Ferrous
Tolerance ± (0.7 µm + 1 % of reading)
Resolution 0.1 µm or < 0.2 % of reading
Min. Area of measurement 5 mm x 5 mm
Minimum radius of curvature Convex 1.5 mm, Concave 5 mm
Minimum thickness of substrate Iron/Steel: 0.2 mm Non-ferrous metals: 50 µm
Surface Temperature -15 °C to 60 °C
Range 0 – 1,500 µm for Iron/Steel (FN & F models) 0 – 1,500 µm for Non-Ferrous metals (FN and N Models)
Substrate Ferrous (FN/F) and Non-Ferrous (FN/N)
Tolerance ± (1 µm + 1 % of reading)
Resolution 0.1 µm or < 0.2 % of reading
Min. Area of measurement 5 mm x 5 mm
Minimum radius of curvature Convex 1.5 mm, Concave 5 mm
Minimum thickness of substrate Iron/Steel: 0.2 mm (FN and F Model) Non-ferrous metals: 50 µm (FN and N Model)
Surface Temperature -15 °C to 60 °C
Minimum ID for measurement (for FN 1.5/90) 12.5 mm
Range0 – 1,500 µm for Iron/Steel
0 – 1,500 µm for Non-Ferrous metals
SubstrateFerrous and Non-Ferrous
Tolerance± (1 µm + 1 % of reading)
Resolution0.1 µm or < 0.2 % of reading
Min. Area of measurement5 mm x 5 mm
Minimum radius of curvature

Convex 1.5 mm, 

Concave 5 mm

Minimum thickness of substrateIron/Steel: 0.2 mm (FN and F Model)
Non-ferrous metals: 50 µm (FN and N Model)
Surface Temperature -15 °C to 60 °C
Minimum ID for measurement 12.5 mm
Range

0 – 3,500 μm – For Iron/Steel

0 – 3,000 μm – For Non-Ferrous substrates

Accuracy

± 3 μm or ± 3 % of reading

(whichever is greater)

Resolution

1 μm for 0 to 1,000 μm

2 μm for 1,000 to 2,500 μm

5 μm for 2,500 to 3,500 μm

Min radius for convex surface5 mm
Min radius for concave surface50 mm
Min measuring area10 mm X 10 mm
Range 0 – 10 mm – For Iron/Steel
Accuracy ± 10 μm or ± 3 % of reading (whichever is greater)
Min radius for convex surface 5 mm
Min radius for concave surface 50 mm
Min measuring area 10 mm X 10 mm

Supported Probes

FN 0.2

Range

0 - 200 µm for Iron/Steel  (FN & F models)
0 - 200 µm for Non-Ferrous metals (FN and N Models)

Substrate

Ferrous and Non-Ferrous

Tolerance

± (0.7 µm + 1 % of reading)

Resolution

0.1 µm or < 0.2 % of reading

Min. Area of measurement

5 mm x 5 mm

Minimum radius of curvature

Convex 1.5 mm,

Concave 5 mm

Minimum thickness of substrate

Iron/Steel: 0.2 mm
Non-ferrous metals: 50 µm

Surface Temperature

 -15 °C to 60 °C

FN 1.5, F 1.5, N 1.5, FN 1.5/90

Range

0 - 1,500 µm for Iron/Steel  (FN & F models)
0 - 1,500 µm for Non-Ferrous metals (FN and N Models)

Substrate

Ferrous (FN/F)and Non-Ferrous (FN/N)

Tolerance

± (1 µm + 1 % of reading)

Resolution

0.1 µm or < 0.2 % of reading

Min. Area of measurement

5 mm x 5 mm

Minimum radius of curvature

Convex 1.5 mm,

Concave 5 mm

Minimum thickness of substrate

Iron/Steel: 0.2 mm (FN and F Model)
Non-ferrous metals: 50 µm (FN and N Model)

Surface Temperature

 -15 °C to 60 °C

Minimum ID for measurement (for FN 1.5/90)

12.5 mm

FN 3.5, F3.5

Range

0 – 3,500 μm -  For Iron/Steel

0 – 3,000 μm -  For Non-Ferrous substrates

Accuracy

± 3 μm or ± 3 % of reading

(whichever is greater)

Resolution

1 μm for 0 to 1,000 μm

2 μm for 1,000 to 2,500 μm

5 μm for 2,500 to 3,500 μm

Min radius for convex surface

5 mm

Min radius for concave surface

50 mm

Min measuring area

10 mm X 10 mm

F10

Range

0 – 10 mm -  For Iron/Steel

Accuracy

± 10 μm or ± 3 % of reading

(whichever is greater)

Min radius for convex surface

5 mm

Min radius for concave surface

50 mm

Min measuring area

10    m X 10 mm

Industries We Serve

Automotive

Automotive

Medical Device & Pharmaceutical

Medical Device & Pharmaceutical

Aerospace

Aerospace

Electronic & Electric Component

Electronic & Electric Component

Chemicals & Petrochemicals

Chemicals & Petrochemicals

Metal Foundries & Casting

Metal Foundries & Casting

Energy, Power & Renewables

Energy, Power & Renewables

Mining & Minerals

Mining & Minerals

Looking for a Custom Measurement Solution?

Our experts will guide you to the right technology.
Scroll to Top